Dimensions & Specifications

High Voltage Pulse Resistors — Dimensions
Rated Power: StandardRated Power: MiniatureφD (mm)L (mm)H (mm)φd (mm)
1/4W1/2WS2.3±0.56.5±128±20.45±0.1
1/2W1WS3.5±0.59.0±1.525±20.50±0.1
1W2WS4.5±1.011.5±1.524±20.60±0.1
2W3WS5.0±1.015.5±1.527±30.65±0.1
3W5WS6.0±0.517.0±1.527±30.70±0.1
5W7WS8.0±1.024.0±1.533±30.75±0.1

Swipe horizontally to view the full table →

Voltage Characteristics

Rated Power: StandardRated Power: MiniatureMaximum Working VoltageMaximum Overload VoltageDielectric Withstand VoltageImpulse Voltage (Surge)
1/4W1/2WS350V700V350V3000V
1/2W1WS500V1000V500V4000V
1W2WS700V1400V500V5000V
2W3WS1000V2000V700V6000V
3W5WS1500V3000V750V7000V
5W7WS2000V4000V1000V8000V

Swipe horizontally to view the full table →

If the rated voltage exceeds the maximum working voltage, use the maximum working voltage.


Electrical Characteristics

Test ItemTechnical RequirementsTest Conditions / Standard
Operating temperature range-55°C to +125°C
Temperature coefficient±500ppm/°CTest temperature: room temperature +100°C
Dielectric withstand voltageNo burning or insulation breakdownApply the AC voltage specified for each rating for 60 seconds
Short-time overload±(1%+0.05Ω)2.5 times rated voltage or 2 times limiting voltage, whichever is lower, for 5 seconds
Temperature cycling±(1%+0.05Ω)-55°C to +125°C, 5 cycles
Moisture resistance under load±(5%+0.1Ω)40°C, 95%RH; rated voltage applied for 1.5 hours ON, 0.5 hours OFF, for 1000 hours
Load life±(5%+0.1Ω)70°C; rated voltage applied for 1.5 hours ON, 0.5 hours OFF, for 1000 hours
Resistance to soldering heat±(1%+0.05Ω)350°C for 3 seconds
SolderabilityCoverage of at least 95%255°C for 3 seconds
Impulse voltageNo burning or insulation breakdownApply voltage for 2.5 seconds ON and 2.5 seconds OFF, for 10 cycles

Swipe horizontally to view the full table →


Technical Details

Load Derating Curve

Y axis: Rated Power (%)

High Voltage Pulse Resistors — Load Derating Curve

X axis: Ambient Temperature (°C)

Product Structure

High Voltage Pulse Resistors — Product Construction
  • A: End cap
  • B: Ceramic core
  • C: Resistive film
  • D: Insulating coating
  • E: Color-code bands
  • F: Lead
  • G: Identification band

Yellow identification band: high-voltage pulse resistor


Looking for a resistor for your project?

Tell us your required specifications, quantity and application. Our team will review your requirements and provide a suitable solution or quotation.